    Wiring an EZEye photocell to HAI OmniProII

    Hi All,     Just received my Leviton 4 relay module.   Can someone please confirm the wiring?   My guess: J1 to Earth GND on OMNI Panel T1 to EZEye White wire (Digital Output) T2 to EZEye Red wire (+12V) Relay 1 NO to OMNI Zone "-" input Relay 2 NO to OMNI Zone "+" input   Correct?  ...
  2. R

    EZEye Smartenit1011A Light Sensor installation in OMNI IIe

    Correction #3 should be T2 to EZEye Red wire (+12V)
  3. R

    EZEye Smartenit1011A Light Sensor installation in OMNI IIe

    Hi All,     Just received my Leviton 4 relay module.   Can someone please confirm the wiring?   My guess: J1 to Earth GND on OMNI Panel T1 to EZEye White wire (Digital Output) T2 to EZEye Green wire (+12V) Relay 1 NO to OMNI Zone "-" input Relay 2 NO to OMNI Zone "+" input   Correct?  ...
  4. R

    EZEye Smartenit1011A Light Sensor installation in OMNI IIe

    Thanks @ano and @DELInstallations! I've ordered the Leviton 4 relay module. Will report back on results. Thanks -- Randy Sent from my iPhone using Tapatalk
  5. R

    EZEye Smartenit1011A Light Sensor installation in OMNI IIe

    Hi all,      I'm installing an outdoor light sensor to my OMNI IIe Panel.    There are 3 inputs: +12V GND Digital    The instructions say to install the Digital input into the Zone Negative input and connect a jumper from the +12V to the same Zone Positive input.      Before connecting up the...
  6. R

    Email notifier board

    Hi All,       I upgraded my PC Access, OMNI IIe and Email Notifier Board to the latest versions and in that order. Everything is operational except for my Email Notifier Board. After the upgrade, I was no longer able to access it from PC Access. When I try to retrieve Version / MAC Address info...
  7. R

    Email Notifier Board NTP Sync

    SOLVED! Did a reset EEPROM then restored a backup. It's all working now! :) Sent from my iPhone using Tapatalk
  8. R

    Email Notifier Board NTP Sync

    OMNI IIe: 3.16 Email notification board: 1.5 It appears as though PCA is unable to update the "Enable Time Sync" field. Possibly a bug in the PCA software? Sent from my iPhone using Tapatalk
  9. R

    Email Notifier Board NTP Sync

    Thanks pete_c! FYI - I tried switching the email notifier board with a new one to test. Same behaviour so it's not the board. Sent from my iPhone using Tapatalk
  10. R

    Email Notifier Board NTP Sync

    Hi Folks,      I've had this board for 2 years now and never checked to see if the "Enable Time Sync" field was set to "Yes". Well, it wasn't and I find my OMNI IIe system controller time fluctuates from time to time. I understand by setting this field to "Yes" there will be an NTP Sync...
  11. R

    OMNIStat2 Questions

    Thanks Ano. Just received a response from Leviton HAI support to the same effect. You are correct. Thx! :) Sent from my iPhone using Tapatalk
  12. R

    OMNIStat2 Questions

    Just heard back from Leviton HAI support. With regards to #1 -- outdoor humidity is not displayed on the OMNIStat2. It's a marketing error on the specs. The humidity being referred to is the indoor humidity reading from the internal OMNIStat2 sensor. Sent from my iPhone using Tapatalk
  13. R

    OMNIStat2 Questions

    Hi All,      I have two questions regarding the OMNIStat2 Thermostat: I have a 31A00-8 Outdoor Temp/Humidity sensor installed and would like to see the readings on the OMNIStat2. I see the Outdoor Temp on messages line, but no Outdoor Humidity. Do I need to configure something special on the...
  14. R

    OMNI IIe Lighting automation script

    Excellent! That did the trick.   Thanks JonW! :)
  15. R

    OMNI IIe Lighting automation script

    Hi All,      I have my front exterior lights dimmed to 50% at midnight.    I want to program it such that when the front motion detector gets tripped (between midnight and dawn), the front exterior lights brighten to 100% for 1 minute then return to 50%.      Seems I can brighten for 1 minute...
  16. R

    OMNIStat2 Automation script

    Thanks picta! That did the trick. It's unfortunate I can't trigger off the OMNIStat2 Mode changing to COOL.   Randy
  17. R

    OMNIStat2 Automation script

    Hi All,     Hopefully this is a simple one ...     I have some logic in my automation scripts to set the HUMIDITY SETPOINT=0 when the OMNIStat2 mode is set to COOL.   Here is my script:   WHEN Main T'Stat SECURE AND IF Main T'Stat SYSTEM MODE IS COOL  THEN Main T'Stat HUMIDIFY SETPOINT 0    ...
  18. R

    OMNI IIe + VRC0P-1LW + Somfy ZRTSI + AeonLab Multisensor 6

    Got it! Thx.   You saved me from buying the wrong bridge (Somfy ZRTSI). :)
  19. R

    OMNI IIe + VRC0P-1LW + Somfy ZRTSI + AeonLab Multisensor 6

    Thanks pete_c! Got it for z-wave motion detectors. I am surprised about the somfy ZRTSI though. The latest OMNI IIe update includes a fix for a somfy command. Thanks, Randy Sent from my iPhone using Tapatalk
  20. R

    OMNI IIe + VRC0P-1LW + Somfy ZRTSI + AeonLab Multisensor 6

    Hi All,      I have a question regarding z-wave compatibility between the OMNI IIe and various z-wave devices using the VRC0P-1LW as the z-wave bridge: Somfy ZRTSI - Will the OMNI IIe recognize all the Somfy commands being translated to z-wave? - Does the OMNI IIe periodically poll the Somfy...