  1. R

    OP2 and Xantech MR88

    Quick question for one of the HAI reps. I've connected a Xantech MR88 to the OP2. According to the HAI website I should get status and control of Power, Volume, Source, Bass, Treble, Balance, Mute, etc. In reality, I can only see/control Power, Volume, Mute and Source but no Bass, Treble or...
  2. R

    "No Controller Data" on OMNI II to OPII upgrade

    I spent the day swapping out my OMNI II for a new OPII. Very straightforward procedure. On initial power-up I only had the console connected and it repeatedly beeped as expected. At the console I am getting "no controller data". I can "4/up arrow" to ensure the console is set as console 1 and...
  3. R

    Event duration logging possible?

    Sorry if this has been asked before. I checked all 30 posts but didn't find it. Back in the day my OMNI II was able to track thermostat run time. Doesn't seem to have that ability anymore but is there a way through automation coding to track the duration of an event? For example, how long a...
  4. R

    Unit/Lighting values in sync

    A question for the folks at HAI. In PC Access, only a single value is shown when using a unit for lighting. In other words, if I use the on/off commands, PC Access will show ON or OFF. If I use the Level command, PC Access will show the light level percentage. One would assume that these two...
  5. R

    Light sensor with HAI OMNI II/OPII

    Does anyone know of a photocell or light sensor similar to the ADI Photo Sensor BobCat that I can attach to the OMNI II or OPII? Thanks, Rick
  6. R

    Z-Wave Frustration

    So I had a few lights without neutrals so I figured z-wave was the way to go. Picked up a few Intermatic switches and a starter kit. Plugged in the ThinkStick, captured my devices in the HA09 remote and transferred them to the TinkStick. All worked fine. The end goal is to have these devices...
  7. R

    Adding 10A17 to OMNI II

    I'm hoping someone from HAI can help with this problem. I added a 10A17 serial board to my OMNI II (not OPII, not IIe). The purpose was to connect it to a Leviton Vizia RF controller (never got that far). It is the second expansion board, the first being a hardwire expander. The HW expander is...
  8. R

    Notifications not available via serial connection

    Questions for HAI tech support: With recent firmware and PCA upgrades, polling the panel for status via 3rd party programs is no longer required - the firmware will now provide notification of changes. Apparently this is only available via ip and therefore only those panels that support ip. It...
  9. R

    RC-80B and PCA 3 questions

    Two questions regarding the RC-80B. I have 3 RC-80B's running flawlessly. Well, almost :) Typical programming for each: higher HSP in the morning, lower during the day, higher in the evening, lower at night. One tstat always jumps to the higher HSP at midnight. Can't figure out why. I had this...
  10. R

    ECM-1240 counting pulses

    There's been a lot of conversation about the ECM-1240 - great product. I have been testing ts little sister the 1220 and it works simply and effectively. Unfortunately there has not been much discussion about 1240's Aux channel 5's ability to count pulses. It appears that Aux 5 is special and...
  11. R

    PC Access problem with Omni II upgrade to chip V3 & PCA 3

    I recently upgraded an OMNI II to V3 of the chip. Also upgraded PC Access to V3. Followed instructions during upgrade and checked for upgrades to software and firmware. All said OK. All seemed to go well during upgrade and PCA3 picked up all of the info from its earlier version. Noticed then...
  12. R

    Suggestions for pulse counter for water meter

    Hoping someone may be able to help me with this one. Now that I have Brultech tracking my electical usage I want to also track my water usage. My water company uses a meter that electronically tracks each gallon used with a pulse. My goal is to get this pulse into my HAI panel where I can track...