Search results

  1. L

    Siren bypass in an NX-8E

    If I unplug the siren the keypads go into an alarm state.  I assume there is a resistor in the actual siren since there isn't one on the panel itself.  On all of the zones, they put the resistor at the panel.  I haven't been able to find what the resistor is on the siren to bypass it when I want...
  2. L

    Interlogix NX-320E

    So I'm thinking of adding an NX-320E to my NX-8E system.  Currently the cabinet is a bit full and since I was going to add multiple rate of rise sensors heat sensors in the attic, I was thinking of putting a cabinet in the attic for the NX-320E along with another NX-216E zone expander to handle...
  3. L

    Attic RoR fire detector

    I have an NX-8e panel and on zone 8 I tried to install a System Sensor 5602 fire/RoR detector.  I only have one and I ran the two wires from the panel (zone 8) to the 5602.  I put the red on one terminal and the black on the second terminal and then had the resistor also attached to the two...
  4. L

    Alarm system monitoring coupon

    I have absolutely no experience with them, but I have a coupon for $25.00 off annual alarm monitoring through alarmsystemstore.com.  The coupon expires January 1st of 2019.  So whoever wants it can have it.  Do your homework and make sure what they offer is what you want, as I stated above, I...
  5. L

    NX-216E on an Interlogix NX-6V2

    So the last thing I'm adding to my panel is one NX-216E to my NX-6V2; I've already added the NX-584E and NX-595E.   Currently two garage doors, an entry garage door, all of the windows, a front door, a backdoor and three French doors are all on six zones.  I've counted 22 wire pairs that makeup...
  6. L

    Interlogix firmware

    Is there a source to get firmware updates from Interlogix or are they behind lock and key?  The NX-595E has a "USBUP" port on it and Interlogix does sell the USB drive to install updates on it, but the actual firmware cannot be found.  Interlogix also sells other products that you can use to...
  7. L

    16.5VAC DIN transformer

    Has anyone ever seen a 16.5VAC transformer?  I need 45VA or greater.  Ideally it would be an industrial or capable of handling a harsh environment.  I have equipment in the attic I have a few DIN rails and would like to move the wall wart out of the inside into the attic and would prefer...
  8. L

    NX-6V2 multiple modules allowed?

    I have an Interlogix NX-6V2 and would like to add both the NX-595E (Ethernet) and the NX-584E (RS-232 serial) module to the same system.  Both connect to the Com and Data bus terminals, can both modules be used at the same time or is it limited to only one?  This is not going to be monitored by...
Back
Top