    UPB switches won't turn off from ELK

    Alright, I have an Elk M1 that is controlling about 20 UPB switches. Up until about 3 weeks ago, everything was working just fine. Now, however, I have some outdoor lights that are not turning off when scheduled. At 10pm they are supposed to turn off, but they are staying on. Even when I...
  2. P

    2 Homes: 3 HAI RC100B Thermostats per home: 2 Frustrated Elkers: 1 Solution?

    Alright, Both a friend of mine and myself have the M1 and 3 HAI RC100B thermostats (oddly enough). All three are hooked up to the M1 through a single XSP. Here is the problem: I can never get all three to be seen by the ELK (2-way communication). There is always one that shows "unit not...
  3. P

    Looking for a kind, sefless Crestron dealer/installer...

    Well, I am currently designing a GUI for my dedicated home theater remote (7" touchscreen). I was browsing around, looking for ideas, and came across this website: www.guifx.com They have some great designs, and one in particular stood out: http://www.guifx.com/store/products/1087 If...
  4. P

    ELK Programming: Bypass motion detection when a light is manually turned off

    Alright, I am wondering how to go about programming my ELK M1 to do the following. I have motion sensors setup to turn on certain lights at night. However, when I want to turn off the light manually, after hitting the dimmer switch to off, the motion sees me and turns the light back on...
  5. P

    iPod Touch + $50 Gift Card + Free Spore Game + Free Shipping = $230

    Dear Cocooners, As you have probably seen through the various discussion on CT and the blog articles, the iPhone/iPod Touch is quickly becoming a very powerful device in the HA/Theater world. With over 20+ HA apps alone, there really isn't much to compare it with. A 3.5" multi-touch...
  6. P

    ELK-M1KAM and 1-wire Temperature Sensor

    Dear Fellows Elkers, In the ELK-M1KAM literature it shows a Dallas 1-Wire iButton being connected directly to the terminals without need for another device or circuit board. I know that the hobby board temperature sensors will work, but can I just use a DS18S20 with wires connected...
  7. P

    DS18B20 and ELK M1KAM??

    Dear Fellow Cocooners, Do you guys know if the DS18B20 temperature sensors will work on the 1-wire bus of the M1KAM?
  8. P

    Can 4 pairs of Cat5e handle this power?

    Alright, I am installing some in-wall low power consumption touchscreens. The max requirement for the screens in terms of power is 12VDC @3.42A, and the power supply is 80W, Input: 90VAC~264VAC @ 50/60Hz Output:12VDC. Is it possible to use all 4 pairs of cat5e to power these? What about 2...
  9. P

    ELO Intellitouch not working properly

    Dear fellow cocooners, Alright. I purchased 2 15" ELO touchscreens from the guy who had them on ebay a few months ago. One is working flawlessly, and I will actually be posting pics of my undercabinet kitchen install of it once finished. However, the other touchscreen has not been as well...
  10. P

    $1169 7" Touchscreen PC running XP

    Jensen Nvx-3000pc 7" Windows Xp Personal Computer W/ Wifi And Gps Navigation UMPC This was first announced at CEDIA 2007. It is marketed as a car pc, but it would be perfect as either a tablet or in-wall touchscreen as it is basically an UMPC. EDIT: Video of device...
  11. P

    Elk + Vonage + ELK-RJSET + Telephone Dist. Module

    Alright, Here is the setup: I do not have phone service over a regular phone line. Instead, I use Vonage with my DSL. So, what I am trying to do is hookup my vonage phone line to the ELK-RJSET for control and monitoring of the ELK-M1. I have the Vonage Linksys PAP2 adaptor...
  12. P

    Door Contacts

    Alright guys, The time has come to start installing the security contacts for the new house. I have chosen to go with the GRI super mini surface mount contacts for all of the windows. However, I need some input on contacts for the doors. I have 3 different needs for contacts on my...
  13. P

    "magic" mirror for home automation announcements!

    Alright, I stumbled upon this at the AVS forums. This looks like such a fun idea for a theater/gameroom/themed room. Here is what AVS has to say about it: For more info go to http://www.themeaddicts.com/pages/mirror.html
  14. P

    500 Gigs for $169

    Was just looking at the Fry's ad this morning and saw a pretty good deal on a harddrive: $169 Seagate 500GB Ultra DMA/100 Hard Drive - Retail Boxed Hard Drive - Backup Software Included NO MAIL IN REBATES
  15. P

    Let the terminating begin!!!

    Alright, Well guys, things are finally starting to take off. The drywall is mudded, taped, and now sprayed. So I no longer have any excuse for not starting to terminate the drops. I am going to start with the "common" drops throughout the house. These are the non-tv areas, and just the...
  16. P

    Test INSTEON now or wait?

    Alright guys, I am about to order my HA system! Yes, its quite exciting to be finally getting some of the stuff I have been researching and watching for months. Anyways, I am getting the Elk M1 Gold, along with the XSP for lighting control. I am also going to be getting some motions...
  17. P

    The Batcave Video

    Alright guys, I have finally gotten a chance to take a short video of the "batcave" (a.k.a the ha/server room) I wanted to post this to get some feedback on how I should run the wires into the room, where I should put the panel, racks, etc. I basically need help in designing the layout for...
  18. P

    Should I Drywall the Batcave??

    IGNORE THIS POST! (Unless you guys understand what I wrote lol) I will post a new one once I get the pictures. PLEASE DELETE ADMINS! Alright guys, The wiring is almost done! We only have about 4 or 5 more runs to do and the pre-wire will be complete! HURRAY! I will be posting the wiring...
  19. P

    1 cat5e for both camera and motion?

    Dear fellow CTers, Alright. I found out today that I need to have 8 motions outside the house for security/motion lighting. However, this was not in the plan for the LV wiring guys bid. However, they already ran for 8 security cameras which would be in the same location as the outdoor...
  20. P

    When to terminate??

    Alright guys, My low voltage wiring is almost complete. They plan on being done on Tuesday. However, I have some issues that need to be dealt with: Firstly, I want to make sure that all of this cable is in working order. Sure it LOOKS ok, but who knows if it actually functions? However, the...