Search results

  1. C

    ELK and wireless windows -- Help needed

    The other solution is to install screens and put the sensor on the screen. Then you get a secure home and open windows :(
  2. C

    M1G Z-wave or UPB status feedback

    Elk is next to useless in keeping track of UPB status. It can turn UPB switches on and off, but it has no idea if you manually turn on or off a switch.There is also no confirmation of receipt, so you can't be sure if the switch received your command from the Elk.
  3. C

    M1G Z-wave or UPB status feedback

    I talk to support:)
  4. C

    M1G Z-wave or UPB status feedback

    Elk is putting all their development effort into their new system. They aren't doing much with the M1(G), as can be seen from the small number of new functions added over the last 18 months.
  5. C

    Rain8 or Not?

    One difference is that you have one. I had to control 29 valves, so I had 4 of them. I also monitored the actual water usage via the inbuilt counter - this also generated additional traffic while watering. The non pro versions are confirmed to have firmware bugs that cause them to fail when...
  6. C

    Rain8 or Not?

    Stay away from any of the rain8upb's - I tried them for over a year and nothing but trouble. The serial one's worked OK. I use elk relays now - switch 24V AC transformers via the elk - works like a charm!
  7. C

    Home Monitoring with M1G

    UPB isn't great with the Elk. No confirmation of receipt. Almost impossible to determine the real status of a UPB device. Also, Elk development seems to have ground to a halt!
  8. C

    Elk M1G + EZrain irrigation controller

    I now have 30+ sprinklers attached to my Elk. Started using UPB - really poor support for UPB via the Elk - no confirmation of receipt, came on when not requested, never know when they were really on. Can't imagine any x10 based system will be any better. In the end, I added more relays...
  9. C

    New Firmware for M1G and M1XEP on ELK website

    There is no async notification of changes to the counter. Elk is aware of the issue. I'm only using counters because no custom settings left. The real problem with Elk, IMHO, is that you raise issues, they commit nothing, and usually do nothing. One never knows whether an issue is ever...
  10. C

    New Firmware for M1G and M1XEP on ELK website

    Well, if that's it, pretty disappointing. Counters still not sticky, still only 20 custom settings, still won't be able to read counters from CQC due to Elk protocol limitations. And as usual, no idea of what's coming out or is going to be supported. Elk has great teck support, but I have to...
  11. C

    ElkRP 2.0.4

    Anyone notice the new features? They seem to be well hidden:)
  12. C

    UPB Challenge

    I had CFL's, no dimming, and MTBF was around 90 days!!!
  13. C

    AprilAire 8870 Help Please

    I had to hook mine up to a pc to debug and get it working. Also had to set the baud rate to 9600.
  14. C

    Issue with Elk and UPB

    I've got around 20 UPB switches. Pretty unhappy. Elk integration is poor, you can't get the real status of the switch. On top of that, you can't run any of the lhigh efficiency lights, as they are flouresant. Mean time to failure on these lights on the UPB system is around 90 days.
  15. C

    Future of Elk M1

    What plan :hesaid:
  16. C

    Seeking very cool home irrigation controller

    Go hard wired. I used the UPB Rain8's and had all sorts of problems! I emded up going Elk relays. They woek fine as long as you can work within the Elk limitations.
  17. C

    poor man's garden sprinkler

    However, if the elk restarts, your custom values are set to zero, and also CQC can't read changes made to custom values made by the elk via rules. Add to this the fact that there is no persistence in CQC and that you can't for example turn your sprinklers on every fourth day (only 4th day of...
  18. C

    Cannot keep IP camera on line

    I had similar problems as well. Returned them and went with Linksys.
  19. C

    Monitoring Service

    I use Alarm Relay, who have been terrific. I use a POTS connection. $109 a year.
  20. C

    Reading and Writing Counter Values

    Treat the counter update just like custom values. If not, then read all counters. Getting really tired not being able to read counters from CQC because Elk does not update them when they are modified from inside rules.
Back
Top